GRIDVAR Static Var Generator

Stepless reactive power compensation. Rated in kvar — sizing follows a reactive power calculation. Three technology tiers on one hardware platform.

GRIDVAR · SVG family

Stepless Reactive Power Compensation

Its primary function is reactive power compensation. It is rated in kvar — sizing follows a reactive power calculation. Harmonic suppression comes from residual capacity. The three tiers share one body platform; what differs is performance and budget.

Standard Series

GRIDVAR-G

Standard Series

Cost-effective active compensation for standard industrial applications. Proven IGBT technology with wide capacity range.

Standard
TechnologyAdvanced IGBT, 3-Level
FunctionSVG · AHF ordered separately
Voltage400V (±20%) / 690V opt.
Module capacity20 – 150 kvar
Response time≤ 5 ms
Harmonic filtering2nd – 25th harmonic
Efficiency> 97.5%
Power factorAdjustable −1 to 1
Max. parallel20 modules
Premium SiC Series

GRIDVAR-X

Premium SiC Series

Silicon Carbide (SiC) switching device. Over 100 kHz switching frequency. 4 µs instantaneous response. Up to 98% efficiency. For steel mills, arc furnaces and the most critical harmonic environments.

Premium SiC
TechnologySilicon Carbide (SiC)
FunctionSVG · AHF ordered separately
Voltage220V – 380V (+10% / −15%)
Module capacity30 – 150 kvar
Response time4 µs (instantaneous)
Switching frequency> 100 kHz
Harmonic filtering2nd – 51st harmonic
EfficiencyUp to 98%
Operating temp.−25°C ~ +55°C
CommunicationBluetooth / Mobile APP, RS485 / CAN / RJ45
Max. parallel10 modules (smart rotation)
Technical Comparison

GRIDVAR Model Comparison

A side-by-side comparison of all three GRIDVAR tiers to help you select the right model for your application.

Parameter GRIDVAR-G
Standard Series
GRIDVAR-C
Compact Series
GRIDVAR-X
Premium SiC Series
Switching technologyAdvanced IGBT, 3-LevelHigh-Density IGBT, 3-LevelSiC MOSFET, 3-Level
SVG function
AHF function
Secondary function on residual capacity
3-Phase load balancing + Neutral
Response time≤ 5 ms≤ 5 ms4 µs / ¼ cycle (fundamental)
Switching frequency20 kHz20 kHz> 100 kHz
System efficiency> 97.5%≥ 97.5%Up to 98%
Harmonic filtering range2nd – 25th2nd – 51st2nd – 51st (ind. selection)
Operating voltage400V (±20%) / 690V opt.400V (−15% ~ +15%)220V – 380V (400V class)
Module capacity (400V)20 – 150 kvar35 – 100 kvar30 – 150 kvar
Max. parallel modules20 modules20 modules10 modules (smart rotation)
Max. cabinet capacity~500 kvar1200 kvar / cabinetOn request
Module heightStandard88 mm (35 & 50 kvar)Compact / High density
Special featuresRS485, CAN Bus, Modbus RTU, Mobile APP, Opt. HMIRS485 / CAN, Opt. HMIBluetooth / Mobile APP, RS485 / CAN / RJ45
Best forPlastics, textiles, general industryRetrofit, MCC, tight cabinet spacesSteel, arc furnaces, critical harmonic environments

Need dedicated harmonic filtering instead? See GRIDSINE

Ready to eliminate power quality problems?

Our engineers will assess your facility and recommend the right GRIDVAR tier and panel configuration.

Contact Engineering
Documents

Technical documents for this product. Ask for a document still in preparation and we will send it as soon as it is ready.

Request a Quote

Tell us about your project and a Forte engineer will respond within 1 business day.

Your information is used only to respond to your inquiry. We do not share your data with third parties.

Forte Teknik A.Ş. · Istanbul, Turkey