Home/Products/Medium Voltage

Medium Voltage Solutions

MV reactive power compensation and voltage stabilization for industrial substations and utility grids. 6 kV to 35 kV, up to 100 Mvar.

Medium Voltage

MV Reactive Power
Compensation Systems

The medium voltage range covers two topologies: thyristor-based SVC and IGBT-based STATCOM. Both are used for reactive power compensation in heavy industry and utility networks.

Operating at voltage levels from 6 kV to 35 kV, these systems provide dynamic voltage regulation, flicker mitigation, power factor correction and harmonic compensation for arc furnaces, rolling mills, wind farms and transmission substations.

6 kV – 35 kV Up to 100 Mvar SVC (TCR+TSC) STATCOM / HV-SVG
View Products ↓
Product Range

Medium Voltage Product Families

Thyristor-based SVC and IGBT-based STATCOM. Ranges below are per family.

Medium Voltage, thyristor-based

SVC (Static VAR Compensator)

TCR + TSC topology for heavy industrial loads, arc furnaces and wind farms.

  • Voltage6 – 35 kV
  • Capacity1 – 100 Mvar
  • Response time< 20 ms
  • TopologyTCR + TSC
  • ApplicationArc furnaces, wind farms, substations
View product details
Medium Voltage, IGBT-based

STATCOM / HV-SVG

IGBT voltage source converter for dynamic reactive power compensation. Faster than SVC, smaller footprint, 4-quadrant operation.

  • Voltage6 – 35 kV
  • Capacity1 – 50 Mvar
  • Response time< 5 ms
  • TopologyMMC / NPC
  • ApplicationVoltage support, harmonic compensation
View product details
Applications

Loads That Cause Flicker and Power Factor Penalties at MV

Large dynamic loads cause voltage fluctuation, flicker and power factor penalties. These are the load types the MV range is applied to.

Arc Furnaces

Electric arc furnaces create extreme reactive power swings and voltage flicker requiring fast MV compensation.

Steel Mills

Rolling mills and meltshops with large motor drives and highly dynamic load profiles at MV level.

Wind & Solar Farms

Renewable energy plants requiring grid code compliance, voltage support and reactive power control.

Utility Substations

Transmission and distribution substations requiring voltage regulation and power factor correction.

Send your substation data. We size the SVC or STATCOM and quote it.

Voltage level, load type and the flicker or power factor problem are enough to start. Feasibility studies and on-site measurements are available.

Request a Quote — Medium Voltage

We reply within 1 business day. Urgent: +90 850 840 64 24

By submitting this form you agree to be contacted by Forte Teknik Makine A.Ş. Your data will not be shared with third parties.

Response within 1 business day